	<item>
		<title>50 Years of Cavitation Research at SVA Potsdam</title>
		<link>https://www.sva-potsdam.de/en/50-years-of-cavitation-research-at-sva-potsdam-2/</link>
		
		<dc:creator><![CDATA[pa]]></dc:creator>
		<pubDate>Wed, 14 Apr 2021 10:59:06 +0000</pubDate>
				<category><![CDATA[Archive]]></category>
		<category><![CDATA[Research]]></category>
		<guid isPermaLink="false">https://www.sva-potsdam.de/?p=7430</guid>

					<description><![CDATA[<p>On the occasion of the 50th anniversary of the cavitation tunnel of SVA Potsdam, we publish ... (updated: September 28th, 2021)</p>
<p>The post <a href="https://www.sva-potsdam.de/en/50-years-of-cavitation-research-at-sva-potsdam-2/">50 Years of Cavitation Research at SVA Potsdam</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>On the occasion of the 50th anniversary of the cavitation tunnel of SVA Potsdam, we publish a series of articles (partly in German) on cavitation research from the archives of SVA. </p>



<ol class="wp-block-list">
<li>(April 14th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1956_-_Gutsche_Kavitationsprobleme_an_Schiffsschrauben_Schiffbautechnik_6._Jg_.pdf" target="_blank" rel="noreferrer noopener" title="http://1956-Gutsche_Kavitationsprobleme-an-Schiffsschrauben_Schiffbautechnik-6.-Jg-.pdf">&#8220;Gutsche 1956, Kavitationsprobleme an Schiffsschrauben&#8221;</a></li>



<li>(April 19th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1959_-_Gutsche_Düsenpropeller_in_Theorie_und_Experiment_Jahrbuch_der_STG_Bd._53.pdf">&#8220;Gutsche 1959, Düsenpropeller in Theorie und Experiment&#8221;</a></li>



<li>(April 22nd, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1962_-_Gutsche_Einfluss_Kav_auf_Profileigenschaften_von_Propblattschnitten_SBF_1_1.pdf">&#8220;Gutsche 1962, Der Einfluss der Kavitation auf die Profileigenschaften von Propellerblattschnitten&#8221;</a></li>



<li>(April 26th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1964_-_Gutsche_Untersuchung_von_Schiffsschrauben_in_schräger_Anströmung_SBF_3_4.pdf">&#8220;Gutsche 1964, Untersuchung von Schiffsschrauben in schräger Anströmung&#8221;</a></li>



<li>(April 29th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1967_-_Schröder_Wirkungsgrad_von_Düsenpropellern_mit_unterschiedlicher_Düsen-_und_Propellerform_SBT_17_8.pdf">&#8220;Schröder 1967, Wirkungsgrad von Düsenpropellern mit unterschiedlicher Düsen-und Propellerform&#8221;</a></li>



<li>(May 3rd, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1971_-_Edel_Zum_Entwurf_gegenläufiger_Propeller_nach_der_Theorie_von_Lerbs_SBF_10_5_6.pdf">&#8220;Edel 1971, Zum Entwurf gegenläufiger Propeller nach der Theorie von Lerbs&#8221;</a></li>



<li>(May 6th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1972_-_Schmidt_Einfluss_Reynoldszahl_und_Rauhigkeit_auf_Propellercharakteristik_SBF_11_3_4.pdf">&#8220;Schmidt 1972, Einfluss der Reynoldszahl und der Rauhigkeit auf die Propellercharakteristik&#8221;</a></li>



<li>(May 11th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1974_-_Dörp_Propeller_mit_voller_Saugseitenkavitation_SBF13_5_6.pdf">&#8220;Dörp 1974, Propeller mit voller Saugseitenkavitation&#8221;</a></li>



<li>(May 14th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1979_-_Mehmel_Meßeinrichtung_für_den_Kavitationskanal_zur_Ermittlung_der_vom_Propeller_ausgehenden_Druckimpulse_Seewirtschaft_11_4.pdf">&#8220;Mehmel 1979, Meßeinrichtung für den Kavitationskanal zur Ermittlung der vom Propeller ausgehenden Druckimpulse&#8221;</a></li>



<li>(May 17th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1980_-_Wagner_Mehmel_Entwicklung_von_Propellern_mit_guten_Gebrauchseigenschaften_SBF_19_1.pdf">&#8220;Wagner, Mehmel 1980, Entwicklung von Propellern mit guten Gebrauchseigenschaften&#8221;</a></li>



<li>(May, 21st, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1981_-_Georgijewskaja_Mawljudow_Mehmel_Methode_zur_Verhersage_der_Kavitationserosion_an_Schiffspropellern_SBF_20_3.pdf">&#8220;Georgijewskaja, Mawljudow, Mehmel 1981, Methode zur Vorhersage der Kavitationserosion an Schiffspropellern&#8221;</a></li>



<li>(May 25th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1983_-_Mehmel_Einfluss_von_Flügelgeometrie_und_Nachstrom_auf_die_Druckimpulse_WPU_Rostock_Naturwissenschaftliche_Reihe_Heft_6.pdf">&#8220;Mehmel 1983, Einfluss von Flügelgeometrie und Nachstrom auf die Druckimpulse&#8221;</a></li>



<li>(May 28th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1983_-_Selke_Erprobung_der_großen_Messstrecke_des_Kavitationstunnels_K15A_der_SVA_Seewirtschaft_15_3.pdf">&#8220;Selke 1983, Erprobung der großen Messstrecke des Kavitationstunnels K15A der SVA&#8221;</a></li>



<li>(May 31st, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1984_-_Schröder_Modellversuche_an_Propellern_für_Querstrahlruder_SBF_23_3.pdf">&#8220;Schröder 1984, Modellversuche an Propellern für Querstrahlruder&#8221;</a></li>



<li>(June 7th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1984_-_Selke_Bestimmung_der_hydrodynamischen_Flügelverstellmomente_von_Verstellpropellern_SBF_23_3.pdf">&#8220;Selke 1984, Bestimmung der hydrodynamischen Flügelverstellmomente von Verstellpropellern&#8221;</a></li>



<li>(June 10th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1986_-_Haimov_Gerchev_Schmidt_Belastungsschwankungen_am_Propeller_eines_Frachtschiffes_mit_großem_Propeller_SBF_25_4.pdf">&#8220;Haimov, Gerchev, Schmidt 1986, Belastungsschwankungen am Propeller eines Frachtschiffes mit großem Propeller&#8221;</a></li>



<li>(June 14th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1987_-_Schmidt_Propellererregte_Druckschwankungen_an_Frachtschiffen_mit_großen_langsamlaufenden_Propellern_SBF_26_3.pdf">&#8220;Schmidt 1987, Propellererregte Druckschwankungen an Frachtschiffen mit großen langsamlaufenden Propellern&#8221;</a></li>



<li>(June 17th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1990_-_Böer_Selke_Junglewitz_Einsatz_der_LDA-Messtechnik_bei_hydrodynamischen_Untersuchungen_am_Kavitationstunnel_SBF_29_2.pdf">&#8220;Böer, Selke, Junglewitz 1990, Einsatz der LDA-Messtechnik bei hydrodynamischen Untersuchungen am Kavitationstunnel&#8221;</a></li>



<li>(June 21st, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1990_-_Selke_Heinke_Propelleruntersuchungen_im_Kavitationstunnel_der_Schiffbau-Versuchsanstalt_Potsdam_STG-Sprechtag.pdf">&#8220;Selke, Heinke 1990, Propelleruntersuchungen im Kavitationstunnel der Schiffbau-Versuchsanstalt Potsdam&#8221;</a></li>



<li>(June 24th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1992_-_Schmidt_Selke_Gerchev_Prediction_of_Propeller-Induced_Pressure_Pulses_SBF_31_1.pdf">&#8220;Schmidt, Selke, Gerchev 1992, Prediction of Propeller-Induced Pressure Pulses&#8221;</a></li>



<li>(June 28th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1995_-_Abdel-Maksoud_u.a._Numerische_Berechnung_der_viskosen_Strömung_um_einen_rotierenden_Propeller_Jahrbuch_der_STG_Bd._89.pdf">&#8220;Abdel-Maksoud et. al. 1995, Numerische Berechnung der viskosen Strömung um einen rotierenden Propeller&#8221;</a></li>



<li>(July 1st, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1995_-_Heinke_Philipp_Development_of_Skew_Blade_Shape_for_a_Ducted_CPP_PROPCAV95.pdf">&#8220;Heinke, Philipp 1995, Development of a Skew Blade Shape for a Ducted CPP&#8221;</a></li>



<li>(July 5th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1995_-_Schulze_Das_Propeller_Entwurfs-_und_Optimierungskonzept_der_SVA_Jahrbuch_der_STG_Bd._89.pdf">&#8220;Schulze 1995, Das Propeller Entwurfs- und Optimierungskonzept der SVA&#8221;</a></li>



<li>(July 8th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1997_-_Schulze_Globale_Optimierung_von_Propellern_STG_Sprechtag_Flensburg.pdf">&#8220;Schulze 1997, Globale Optimierung von Propellern&#8221;</a></li>



<li>(July 12th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1998_-_Bertelo_Schulze_et.al._LIUTO_Development_and_Optimisation_of_the_Propulsion_System_PRADS_1998_The_Hague.pdf">&#8220;Bertelo, Schulze, et.al. 1998, LIUTO Development and Optimisation of the Propulsion System&#8221;</a></li>



<li>(July 15th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1998_-_Bohm_Jürgens_Linear-Jet_-_A_Propulsion_System_for_fast_Ships_PRADS_1998_The_Hague.pdf">&#8220;Bohm, Jürgens 1998, Linear-Jet &#8211; A Propulsion System for fast Ships&#8221;</a></li>



<li>(July 19th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/1999_-_Abdel-Maksoud_Heinke_Viscous_Flow_Around_Modern_Propulsion_Systems_CFD_1999_Ulsteinvik.pdf">&#8220;Abdel-Maksoud, Heinke 1999, Viscous Flow Around Modern Propulsion Systems&#8221;</a></li>



<li>(July 22nd, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2000_-_Heinke_Untersuchung_von_Schicht-_Blasen-_und_Wolkenkavitation_und_der_damit_verbundenen_Erosionsprobleme_23._BMBF-Statusseminar_Rostock.pdf">&#8220;Heinke 2000, Untersuchung von Schicht-, Blasen- und Wolkenkavitation und der damit verbundenen Erosionsprobleme&#8221;</a></li>



<li>(July 25th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2000_-_Kaul_Heinke_Maksoud_Hydrodynamische_Optimierung_von_Podded_Drives_54._STG_FA_Schiffshydrodynamik.pdf">&#8220;Kaul, Heinke, Maksoud 2000, Hydrodynamische Optimierung von Podded Drives&#8221;</a></li>



<li>(July 29th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2001_-_Heinke_Abdel-Maksoud_Untersuchung_der_Umströmung_von_Düsenpropellern_Beiträge_zur_Strömungsmechanik_TUD.pdf">&#8220;Heinke, Abdel-Maksoud 2001, Untersuchung der Umströmung von Düsenpropellern&#8221;</a></li>



<li>(August 2nd, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2001_-_Heinke_Podded_drives_for_navy_ships_STG-Sprechtag_Potsdam.pdf">&#8220;Heinke 2001, Podded drives for navy ships&#8221;</a></li>



<li>(August 5th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2002_-_Abdel-Maksoud_Heinke_Scale_Effects_on_Ducted_Propellers_ONR02_Fukuoka.pdf">&#8220;Abdel-Maksoud, Heinke 2002, Scale Effects on Ducted Propellers&#8221;</a></li>



<li>(August 9th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2003_-_Abdel-Maksoud_Numerical_and_Experimental_Study_of_Cavitation_Behaviour_of_a_Propeller_STG-Sprechtag_Hamburg.pdf">&#8220;Abdel-Maksoud 2003, Numerical and Experimental Study of Cavitation Behaviour of a Propeller&#8221;</a></li>



<li>(August 12th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2004_-_Heinke_Investigations_about_the_Forces_and_Moments_at_Podded_Drives_T-Pod_Conference_Newcastle.pdf">&#8220;Heinke 2004, Investigations about the Forces and Moments at Podded Drives&#8221;</a></li>



<li>(August 16th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2004_-_Maksoud_u.a._Numerical_and_Experimental_Investigation_of_the_Hub_Vortex_Flow_of_a_Marine_Propeller_ONR04_St._Johns.pdf">&#8220;Maksoud et al. 2004, Numerical and Experimental Investigation of the Hub Vortex Flow of a Marine Propeller&#8221;</a></li>



<li>(August 19th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2005_-_Heinke_Rieck_Steinwand_Hocheffektive_Ruder_Schiffbautag_MV_Rostock_Warnemünde.pdf">&#8220;Heinke, Rieck, Steinwand 2005, Hocheffektive Ruder&#8221;</a></li>



<li>(August 23rd, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2006_-_Jürgens_Heinke_Untersuchung_tiefgetauchter_Waterjets_Jahrbuch_der_STG_Bd._100.pdf">&#8220;Jürgens, Heinke 2006, Untersuchung tiefgetauchter Waterjets&#8221;</a></li>



<li>(August 26th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2007_-_Anschau_A_Stereo_PIV_System_for_Investigations_of_Flow_Fields_in_Towing_Tank_and_Cavitation_Tunnel_HYDRONAV_2007.pdf">&#8220;Anschau, Mach 2007, A Stereo PIV System for Investigations of Flow Fields in Towing Tank and Cavitation Tunnel&#8221;</a></li>



<li>(August 30th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2007_-_Anschau_Numerische_und_experimentelle_Untersuchung_eines_Propellers_in_4_Quadranten_STG.pdf">&#8220;Anschau, Lamprecht, Mach, Rieck 2007, Numerische und experimentelle Untersuchung eines Propellers in 4 Quadranten&#8221;</a></li>



<li>(September 2nd, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2008_-_Mertes_Heinke_Aspects_of_design_procedure_for_Propellers_Providing_Maximum_Bollard_Pull_ITS_2008_Singapore.pdf">&#8220;Mertes, Heinke 2008, Aspects of design procedure for Propellers Providing Maximum Bollard Pull&#8221;</a></li>



<li>(September 6th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2009_-_Heinke_Schulze_Steinwand_SVA_High-Speed_Propeller_Series_FAST_2009_Athens.pdf">&#8220;Heinke, Schulze, Steinwand 2009, SVA High-Speed Propeller Series&#8221;</a></li>



<li>(September 9th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2009_-_Jürgens_Heinke_Voith_Schneider_Propeller_(VSP)_-_Investigations_of_the_cavitation_behaviour_OSV_Singapore.pdf">&#8220;Jürgens, Heinke 2009, Voith Schneider Propeller (VSP) &#8211; Investigations of the cavitation behaviour&#8221;</a></li>



<li>(September 10th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2009_-_Rieck_u.a._Druckschwankungen_höherer_Ordnung_am_Hinterschiff_BMWi_Statustagung_Schiffbau_und_Meerestechnik.pdf">&#8220;Rieck, et al. 2009, Druckschwankungen höherer Ordnung am Hinterschiff&#8221;</a></li>



<li>(September 13th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2011_-_Heinke_Hellwig-Rieck_Investigation_of_Scale_Effects_on_Ships_with_a_WED_or_VGF_smp11_Hamburg.pdf">&#8220;Heinke, Hellwig-Rieck 2011, Investigation of Scale Effects on Ships with a WED or VGF&#8221;</a></li>



<li>(September 14th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2011_-_Schulze_Weber_The_new_FORTJES_Z-drive_from_REINTJES_with_contra_rotating_propellers_FAST_2011_Honolulu.pdf">&#8220;Schulze, Weber 2011, The new FORTJES Z-drive from REINTJES with contra rotating propellers&#8221;</a></li>



<li>(September 15th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2015_-_Kleinwächter_Hellwig-Rieck_Heinke_PIV_as_a_Novel_Full-Scale_Measurement_Technique_in_Cavitation_Research_smp15_Austin.pdf">&#8220;Kleinwächter, Hellwig-Rieck, Heinke 2015, PIV as a Novel Full-Scale Measurement Technique in Cavitation Research&#8221;</a></li>



<li>(September 16th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2016_-_Berger_Klose_Efficient_Numerical_Investigation_of_Propeller_Cavitation_Phenomena_causing_Higher-Order_Hull_Pressure_Fluctuations_SNH2016.pdf">&#8220;Berger, Klose 2016, Efficient Numerical Investigation of Propeller Cavitation Phenomena causing Higher-Order Hull Pressure Fluctuations&#8221;</a></li>



<li>(September 17th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2016_-_Schulze_A_new_friction_correction_method_for_open_water_characteristics_of_propellers_Jahrbuch_der_STG_Bd._110.pdf">&#8220;Schulze 2016, A new friction correction method for open water characteristics of propellers&#8221;</a></li>



<li>(September 20th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2017_-_Kleinsorge_Klose_Case_Study_for_the_Determination_of_Propeller_Emitted_Noise_by_Experimental_and_Computational_Methods_smp17.pdf">&#8220;Kleinsorge, Klose 2017, Case Study for the Determination of Propeller Emitted Noise by Experimental and Computational Methods&#8221;</a></li>



<li>(September 21st, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2017_-_Klose_Schulze_Hellwig-Rieck_Investigation_of_Prediction_Methods_for_Tip_Rake_Propellers_smp17_Espoo.pdf">&#8220;Klose, Schulze, Hellwig-Rieck 2017, Investigation of Prediction Methods for Tip Rake Propellers&#8221;</a></li>



<li>(September 22nd, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2017_-_Viitanen_Lübke_Klose_et._al._CFD_and_CHA_simulation_of_underwater_noise_induced_by_a_marine_propeller_in_two-phase_flows_smp17.pdf">&#8220;Viitanen, Lübke, Klose et al. 2017, CFD and CHA simulation of underwater noise induced by a marine propeller in two-phase flows&#8221;</a></li>



<li>(September 23rd, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2018_-_Schulze_Analyse_des_Hochfrequenzspektrums_von_Propellergeräuschen_zur_Detektion_von_STG.pdf">&#8220;Schulze 2018, Analyse des Hochfrequenzspektrums von Propellergeräuschen zur Detektion von Kavitationserosion&#8221;</a></li>



<li>(September 24th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2019_-_Heinke_Hellwig-Rieck_Lübke_Open_Water_Characteristics_of_Propellers_with_Short_Chord_Lengths_smp19_Rome.pdf">&#8220;Heinke, Hellwig-Rieck 2019, Lübke Open Water Characteristics of Propellers with Short Chord Lengths&#8221;</a></li>



<li>(September 27th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2019_-_Schulze_Entwurf_geräuschoptimierter_Propeller_für_Mehrschrauber_Jahrbuch_der_STG_Bd._113.pdf">&#8220;Schulze 2019, Entwurf geräuschoptimierter Propeller für Mehrschrauber&#8221;</a></li>



<li>(September 28th, 2021) <a href="https://www.sva-potsdam.de/wp-content/uploads/2021/04/2019_-_Schulze_Sea-Trial_Auswertung_mit_eingeschränkten_Informationen_und_dynamischen_Einflüssen_Jahrbuch_der_STG_Bd._113.pdf">&#8220;Schulze 2019, Sea-Trial Auswertung mit eingeschränkten Informationen und dynamischen Einflüssen&#8221;</a></li>
</ol>



<p></p><p>The post <a href="https://www.sva-potsdam.de/en/50-years-of-cavitation-research-at-sva-potsdam-2/">50 Years of Cavitation Research at SVA Potsdam</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Outdoor Model Tests for the Evaluation of the Manoeuvrability of an „Inland Waterways Container Ship“</title>
		<link>https://www.sva-potsdam.de/en/outdoor-model-tests-for-the-evaluation-of-the-manoeuvrability-of-an-inland-waterways-container-ship/</link>
		
		<dc:creator><![CDATA[pa]]></dc:creator>
		<pubDate>Mon, 04 Dec 2017 15:33:44 +0000</pubDate>
				<category><![CDATA[Archive]]></category>
		<guid isPermaLink="false">https://www.sva-potsdam.de/?p=6393</guid>

					<description><![CDATA[<p>As part of an industrial project for the American Patriot Holdings LLC (APH) dealing with a new concept of an inland waterways container carrier (designed by NaviForm Consulting &#38; Research), outdoor manoeuvring tests were conducted to complement the standard resistance and propulsion tests. The manoeuvring tests were performed in a sheltered little bay of the Berlin part of the river Havel in the city of Spandau. The approximately 9&#160;m long ship model (scale: 20) was manufactured at SVA Potsdam and,</p>
<p>The post <a href="https://www.sva-potsdam.de/en/outdoor-model-tests-for-the-evaluation-of-the-manoeuvrability-of-an-inland-waterways-container-ship/">Outdoor Model Tests for the Evaluation of the Manoeuvrability of an „Inland Waterways Container Ship“</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></description>
										<content:encoded><![CDATA[<div id="idTextPanel" class="jqDnR">
<div class="sva_bild_floatLFT">
<p><a title="Conceptual Design NaviForm." href="https://www.sva-potsdam.de/wp-content/uploads/2017/12/Concept_NaviForm.png"><img fetchpriority="high" decoding="async" class="alignnone wp-image-6370" src="https://www.sva-potsdam.de/wp-content/uploads/2017/12/Concept_NaviForm-392x275.png" alt="" width="450" height="316" srcset="https://www.sva-potsdam.de/wp-content/uploads/2017/12/Concept_NaviForm-392x275.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Concept_NaviForm-768x539.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Concept_NaviForm-114x80.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Concept_NaviForm-474x332.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Concept_NaviForm-452x317.png 452w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Concept_NaviForm-693x486.png 693w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Concept_NaviForm.png 800w" sizes="(max-width: 450px) 100vw, 450px" /></a></p>
<p><a title="3D CAD model of the ship." href="https://www.sva-potsdam.de/wp-content/uploads/2017/12/3D_CAD_NaviForm.png"><img decoding="async" class="alignnone wp-image-6369" src="https://www.sva-potsdam.de/wp-content/uploads/2017/12/3D_CAD_NaviForm-392x198.png" alt="" width="450" height="227" srcset="https://www.sva-potsdam.de/wp-content/uploads/2017/12/3D_CAD_NaviForm-392x198.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/3D_CAD_NaviForm-768x388.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/3D_CAD_NaviForm-114x58.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/3D_CAD_NaviForm-474x239.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/3D_CAD_NaviForm-473x239.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/3D_CAD_NaviForm-727x367.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/3D_CAD_NaviForm.png 800w" sizes="(max-width: 450px) 100vw, 450px" /></a></p>
<p><a title="Turning circle manoeuvre." href="https://www.sva-potsdam.de/wp-content/uploads/2017/12/Drehkreis_NaviForm.png"><img decoding="async" class="alignnone wp-image-6518" src="https://www.sva-potsdam.de/wp-content/uploads/2017/12/Drehkreis_NaviForm-392x221.png" alt="" width="450" height="253" srcset="https://www.sva-potsdam.de/wp-content/uploads/2017/12/Drehkreis_NaviForm-392x221.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Drehkreis_NaviForm-768x432.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Drehkreis_NaviForm-114x64.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Drehkreis_NaviForm-474x267.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Drehkreis_NaviForm-473x266.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Drehkreis_NaviForm-727x409.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Drehkreis_NaviForm.png 800w" sizes="(max-width: 450px) 100vw, 450px" /></a></p>
<p><a title="Outdoor manoeuvring model tests." href="https://www.sva-potsdam.de/wp-content/uploads/2017/12/Manoeuvering_NaviForm.png"><img loading="lazy" decoding="async" class="alignnone wp-image-6517" src="https://www.sva-potsdam.de/wp-content/uploads/2017/12/Manoeuvering_NaviForm-392x261.png" alt="" width="450" height="300" srcset="https://www.sva-potsdam.de/wp-content/uploads/2017/12/Manoeuvering_NaviForm-392x261.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Manoeuvering_NaviForm-768x512.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Manoeuvering_NaviForm-114x76.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Manoeuvering_NaviForm-474x316.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Manoeuvering_NaviForm-473x315.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Manoeuvering_NaviForm-727x484.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Manoeuvering_NaviForm.png 800w" sizes="auto, (max-width: 450px) 100vw, 450px" /></a></p>
<p><a title="Wave system." href="https://www.sva-potsdam.de/wp-content/uploads/2017/12/Wellenbildung_NaviForm.png"><img loading="lazy" decoding="async" class="alignnone wp-image-6516" src="https://www.sva-potsdam.de/wp-content/uploads/2017/12/Wellenbildung_NaviForm-392x221.png" alt="" width="450" height="253" srcset="https://www.sva-potsdam.de/wp-content/uploads/2017/12/Wellenbildung_NaviForm-392x221.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Wellenbildung_NaviForm-768x432.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Wellenbildung_NaviForm-114x64.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Wellenbildung_NaviForm-474x267.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Wellenbildung_NaviForm-473x266.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Wellenbildung_NaviForm-727x409.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2017/12/Wellenbildung_NaviForm.png 800w" sizes="auto, (max-width: 450px) 100vw, 450px" /></a></p>
</div>
<div class="sva_text_container">
<p>As part of an industrial project for the American Patriot Holdings LLC (APH) dealing with a new concept of an inland waterways container carrier (designed by NaviForm Consulting &amp; Research), outdoor manoeuvring tests were conducted to complement the standard resistance and propulsion tests.</p>
<p>The manoeuvring tests were performed in a sheltered little bay of the Berlin part of the river Havel in the city of Spandau. The approximately 9&nbsp;m long ship model (scale: 20) was manufactured at SVA Potsdam and, in accordance to NaviForm specifications, equipped with modelled superstructures and stylized containers. The ship was propelled by 4 VSPs, of which 2 were used solely for propulsion and the others mainly for manoeuvring purposes. The drives were provided by Voith Turbo GmbH &amp; Co. KG. In the manoeuvring tests straight line, turning on the dime, turning circle and dock moving sidewise tests were conducted.</p>
<p>The tests were performed for a single draught. The thrust distribution scheme for the 4 drives which was identified as the best during previously conducted towing tank tests was also used in the outdoor tests. For full scale speeds of 8 kn and 12 kn straight line and turning circle manoeuvres were demonstrated.</p>
<p>The model tests were documented with video recordings. Beside a stationary camera a quadrocopter drone was used that provided recordings from different views of the manoeuvring behaviour of the ship.</p>
<p>The results showed that the targeted speed of 12 kn in straight line test could easily be achieved with the optimized thrust distribution scheme for the 4 VSPs. A turning circle with a diameter of less than 7 ship lengths can be achieved for a velocity of 8 kn and a thrust direction of 10°. At 12 kn the diameter of the turning circle spans about 7 ship lengths.</p>
<p>Due to the utilization of a purpose built wing system at the ship’s bow a considerably reduced wave system could be observed even at a speed of 12 kn.</p>
<p>In general a very good manoeuvring performance could be demonstrated for this inland waterways container carrier.</p>
<p>&nbsp;</p>
<p>Author: Dr.-Ing. Matthias Fröhlich, Schiffbau-Versuchsanstalt Potsdam GmbH</p>
<div class="sva_clear"></div>
</div>
</div><p>The post <a href="https://www.sva-potsdam.de/en/outdoor-model-tests-for-the-evaluation-of-the-manoeuvrability-of-an-inland-waterways-container-ship/">Outdoor Model Tests for the Evaluation of the Manoeuvrability of an „Inland Waterways Container Ship“</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Friction Measurements of Different Coatings in a Friction Tunnel</title>
		<link>https://www.sva-potsdam.de/en/friction-measurements-of-different-coatings-in-a-friction-tunnel/</link>
		
		<dc:creator><![CDATA[pa]]></dc:creator>
		<pubDate>Tue, 16 May 2017 09:48:43 +0000</pubDate>
				<category><![CDATA[Archive]]></category>
		<guid isPermaLink="false">http://www.sva-potsdam.de/?p=5879</guid>

					<description><![CDATA[<p>It is well known that the frictional resistance of a ship is a substantial part of its total resistance (around 25 up to 75 %). This is mainly influenced by the surface texture of the hull skin, which depends for example on the coating or on the degree of fouling. With respect to power consumption reduction it therefore can be meaningful to minimise the frictional resistance by applying special coatings or surface textures. The requirements for these coatings are low</p>
<p>The post <a href="https://www.sva-potsdam.de/en/friction-measurements-of-different-coatings-in-a-friction-tunnel/">Friction Measurements of Different Coatings in a Friction Tunnel</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></description>
										<content:encoded><![CDATA[<div id="idTextPanel" class="jqDnR">
<div class="sva_bild_floatLFT">
<p><a title="Total view of the friction tunnel." href="http://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand.png"><img loading="lazy" decoding="async" class="alignnone wp-image-5829" src="http://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand-392x261.png" alt="" width="450" height="300" srcset="https://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand-392x261.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand-114x76.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand-474x316.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand-473x315.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand-727x486.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand.png 756w" sizes="auto, (max-width: 450px) 100vw, 450px" /></a></p>
<p><a title="Open test section with pressure sensor bank." href="http://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand_offen.png"><img loading="lazy" decoding="async" class="alignnone wp-image-5831" src="http://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand_offen-392x157.png" alt="Offene Messstrecke des Reibunsgmessstandes." width="450" height="180" srcset="https://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand_offen-392x157.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand_offen-114x46.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand_offen-474x190.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand_offen-473x190.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand_offen-727x291.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Reibungsmessstand_offen.png 756w" sizes="auto, (max-width: 450px) 100vw, 450px" /></a></p>
<p><a title="Example for fouling on a ship hull." href="http://www.sva-potsdam.de/wp-content/uploads/2017/05/Hull_Fouling.png"><img loading="lazy" decoding="async" class="alignnone wp-image-5828" src="http://www.sva-potsdam.de/wp-content/uploads/2017/05/Hull_Fouling-392x294.png" alt="" width="450" height="338" srcset="https://www.sva-potsdam.de/wp-content/uploads/2017/05/Hull_Fouling-392x294.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Hull_Fouling-114x86.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Hull_Fouling-474x356.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Hull_Fouling-423x317.png 423w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Hull_Fouling-648x486.png 648w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Hull_Fouling.png 756w" sizes="auto, (max-width: 450px) 100vw, 450px" /></a></p>
<p><a title="Test plates after exposition to North Sea at LimnoMar for 6 month." href="http://www.sva-potsdam.de/wp-content/uploads/2017/05/Testplatten.png"><img loading="lazy" decoding="async" class="alignnone wp-image-5832" src="http://www.sva-potsdam.de/wp-content/uploads/2017/05/Testplatten-392x186.png" alt="" width="450" height="213" srcset="https://www.sva-potsdam.de/wp-content/uploads/2017/05/Testplatten-392x186.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Testplatten-114x54.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Testplatten-474x224.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Testplatten-473x224.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Testplatten-727x344.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Testplatten.png 756w" sizes="auto, (max-width: 450px) 100vw, 450px" /></a></p>
<p><a title="Microscopic photo of “perfect” riblets and “simple” riblets made with sandpaper." href="http://www.sva-potsdam.de/wp-content/uploads/2017/05/Riblets_kombi.png"><img loading="lazy" decoding="async" class="alignnone wp-image-5835" src="http://www.sva-potsdam.de/wp-content/uploads/2017/05/Riblets_kombi-392x145.png" alt="" width="450" height="167" srcset="https://www.sva-potsdam.de/wp-content/uploads/2017/05/Riblets_kombi-392x145.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Riblets_kombi-768x285.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Riblets_kombi-114x42.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Riblets_kombi-474x176.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Riblets_kombi-473x175.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Riblets_kombi-727x270.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2017/05/Riblets_kombi.png 917w" sizes="auto, (max-width: 450px) 100vw, 450px" /></a></p>
</div>
<div class="sva_text_container">
It is well known that the frictional resistance of a ship is a substantial part of its total resistance (around 25 up to 75 %). This is mainly influenced by the surface texture of the hull skin, which depends for example on the coating or on the degree of fouling. With respect to power consumption reduction it therefore can be meaningful to minimise the frictional resistance by applying special coatings or surface textures. The requirements for these coatings are low friction and anti-fouling properties as well as long service times and resistance to mechanical impacts regarding ice, tugs or fenders. With the help of the friction tunnel of the SVAtech the friction characteristics of these coatings can be measured. Long term tests give answers how fouling and imperfections affect the friction characteristics of the coating.</p>
<p>The frictional resistance of a one-sided wetted flat plate is well known from semi-empirical investigations. There are several formulas for laminar and turbulent flow, developed by e.g. Blasius, Prandtl, Schönherr, Schlichting/Gersten, etc. For Schlichting/Gersten also the roughness of the surface is included, but when dealing with complex surface structures a mere roughness consideration is not enough.</p>
<p>In this case, measurements as with SVAtech’s friction tunnel are still meaningful for providing reliable results in an easy way. Put simply, the friction tunnel is a small water circuit tank in which plates with the coating to be investigated can be installed. Therefore two of these plates form a narrow rectangular channel for which the wall shear stress inside can be derived from the pressure loss between several observation points. In SVAtech’s friction tunnel 12 equidistant positions over the length of the test plates are used for measuring the pressure drop.  Finally, the friction coefficient is obtained by dividing the wall shear stress by the dynamic pressure.</p>
<p>The friction tunnel was developed in 1992 at the Research Institute for Hydraulic Engineering and Shipbuilding (Versuchsanstalt für Wasserbau und Schiffbau) in Berlin and was property of the Technical University from Berlin for a long time until in 2004 SVA bought it. To reach the high accuracy demands of the customers several modifications were necessary. The test section was extended to 12 pressure sensors and a venting valve for each pressure sensor to ensure that no air bubbles are trapped inside the circuit. A magnetic inductive flow meter helps determining the water velocity in the test section. There is a choice of two different flow meters (one covering the small and one the high water speed ranges). Furthermore, 2 temperature sensors were installed to determine the water properties like density and viscosity. A microprocessor automatically runs the engine control of the pump and conducts the calculation of the fitted pressure gradient and friction coefficient. The data is transferred to a computer where the final evaluation is done.</p>
<p>The test procedure is fully automated in such a way that the whole speed range from 1 m/s up to 18 m/s (or respectively log(Re) = 5.4 up to 6.7) is measured in 26 steps three times. For each step there is a waiting time of 60 s for the stabilization of the flow and finally 15 s of measurement time. In the end the mean value curve of all three runs is calculated.</p>
<p>The usual way to present the results of friction measurements is in dependency of the Reynolds number. The challenge is to make the channel flow comparable with a flow around a body as for ship applications. The solution is to determine experimentally the reference length for the calculation of the Reynolds number in such a way that it equals a flow around a body. With the resulting reference length (which is almost the channel perimeter) a good accordance with the ITTC’57 curve is reached for technically smooth plates.</p>
<p>For textures a presentation over s+ can be more meaningful than the Reynolds number. The s+ value is the dimensionless characteristic length for one structure element, e.g. for riblet structures it is the distance of two riblets.</p>
<p>Different measurements were carried out. Good results were achieved with the former anti-fouling spray “Biotard”. For a wide range of Reynolds numbers the friction coefficient is slightly lower than that of the smooth plate. A bigger effect is visible when using  riblets which –  in a defined s+ range – can cause a significant reduction of the friction. During the investigations of riblet structures the idea came up to test “simple” riblets made by hand with sandpaper and a belt grind. The resulting structure is similar to the perfect riblet structure. The maximum friction reduction is not as big as for the perfect riblets but the Reynolds number range is wider for which the friction is lower than that of a smooth plate.</p>
<div class="sva_bild_floatBTN" style="margin: 0 auto; width: 95%;"><a title="Friction characteristic of a technically smooth plate measured in the friction tunnel." href="https://www.sva-potsdam.de/wp-content/uploads/2017/05/Diag_1_gross.png"><img loading="lazy" decoding="async" class="alignnone wp-image-5825" src="http://www.sva-potsdam.de/wp-content/uploads/2017/05/Diag_1_gross-392x277.png" alt="" width="250" height="177"></a><a title="Friction characteristic of a plate coated with the anti-fouling spray “Biotard”." href="http://www.sva-potsdam.de/wp-content/uploads/2017/05/Diag_2_gross.png"><img loading="lazy" decoding="async" class="alignnone wp-image-5826" src="http://www.sva-potsdam.de/wp-content/uploads/2017/05/Diag_2_gross-392x278.png" alt="" width="250" height="177"></a><a title="Friction characteristic of a plate grinded with sandpaper longitudinal to flow (“simple” riblets)." href="http://www.sva-potsdam.de/wp-content/uploads/2017/05/Diag_3_gross.png"><img loading="lazy" decoding="async" class="alignnone wp-image-5827" src="http://www.sva-potsdam.de/wp-content/uploads/2017/05/Diag_3_gross-392x277.png" alt="" width="250" height="177"></a></div>
<div class="sva_clear"></div>
<p>&nbsp;<br />
But it must not be forgotten that not only the “fresh” coating has to be investigated. It is also important to test the long term qualification after several months of operation. SVAtech simulates this in cooperation with the Laboratory LimnoMar where the test plates are exposed to the North Sea for a certain period of time. After this time the plates are tested again in the friction tunnel.</p>
<p>In summary, the friction tunnel provides friction characteristics of different coatings and textures in an easy and cheap way. The real surface and not only a model of it can be measured over a wide range of Reynolds number. A quick answer regarding the drag reduction and hence fuel savings can be given. The measurements are applicable for a wide field not only in the shipbuilding industry but also for the aerospace or automotive industry.</p>
</div>
<p>Author: M. Sc. Rhena Klose, Schiffbau-Versuchsanstalt Potsdam GmbH</p>
<p>The full text can be found in:<br />
R. Klose, R. Schulze: Friction Measurements of Different Coatings in a Friction Tunnel, Proceedings 2nd Hull Performance &amp; Insight Conference, 2017</p>
</div><p>The post <a href="https://www.sva-potsdam.de/en/friction-measurements-of-different-coatings-in-a-friction-tunnel/">Friction Measurements of Different Coatings in a Friction Tunnel</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Calculation Method for the Design of Roll Damping Tanks</title>
		<link>https://www.sva-potsdam.de/en/calculation-method-for-the-design-of-roll-damping-tanks/</link>
		
		<dc:creator><![CDATA[pa]]></dc:creator>
		<pubDate>Tue, 08 Nov 2016 14:16:59 +0000</pubDate>
				<category><![CDATA[Archive]]></category>
		<guid isPermaLink="false">http://www.sva-potsdam.de/?p=5792</guid>

					<description><![CDATA[<p>Within the framework of the research project ROLLTANK sponsored by the BMWI, a method for improving the determination of the flow processes in roll damping tanks was developed. The improved design of this type of installation can be used with a view to an optimum seakeeping behavior of a ship. The method development was supported by accompanying laboratory tests. In addition to investigations of a laboratory model of a RoPax vessel in the towing tank, further useful data for the</p>
<p>The post <a href="https://www.sva-potsdam.de/en/calculation-method-for-the-design-of-roll-damping-tanks/">Calculation Method for the Design of Roll Damping Tanks</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></description>
										<content:encoded><![CDATA[<div id="idTextPanel" class="jqDnR">
<div class="sva_bild_floatLFT">
<p><a title="Roll Damping Test Stand." href="http://www.sva-potsdam.de/wp-content/uploads/2016/11/rolltank.png"><img loading="lazy" decoding="async" class="alignnone wp-image-5757 size-medium" title="Rollkrängungsanlage der SVA Potsdam." src="http://www.sva-potsdam.de/wp-content/uploads/2016/11/rolltank-392x253.png" alt="rolltank" width="392" height="253" srcset="https://www.sva-potsdam.de/wp-content/uploads/2016/11/rolltank-392x253.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/rolltank-768x495.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/rolltank-114x74.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/rolltank-474x306.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/rolltank-473x305.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/rolltank-727x469.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/rolltank.png 800w" sizes="auto, (max-width: 392px) 100vw, 392px" /></a></p>
<p><a title="Vortex Formation on the Bulkhead of a Box Tank." href="http://www.sva-potsdam.de/wp-content/uploads/2016/11/video_shots.png"><img loading="lazy" decoding="async" class="alignnone wp-image-5760 size-medium" title="Wirbelausbildung am Flügelschott eines Boxtanks." src="http://www.sva-potsdam.de/wp-content/uploads/2016/11/video_shots-392x260.png" alt="video_shots" width="392" height="260" srcset="https://www.sva-potsdam.de/wp-content/uploads/2016/11/video_shots-392x260.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/video_shots-768x509.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/video_shots-114x76.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/video_shots-474x314.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/video_shots-473x313.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/video_shots-727x482.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/video_shots.png 800w" sizes="auto, (max-width: 392px) 100vw, 392px" /></a></p>
<p><a title="Box Tank in the Laboratory Model in the Towing Tank." href="http://www.sva-potsdam.de/wp-content/uploads/2016/11/tank_blue.png"><img loading="lazy" decoding="async" class="alignnone wp-image-5758 size-medium" title="Modell mit Boxtank beim Rolldämpfungsversuch." src="http://www.sva-potsdam.de/wp-content/uploads/2016/11/tank_blue-392x147.png" alt="tank_blue" width="392" height="147" srcset="https://www.sva-potsdam.de/wp-content/uploads/2016/11/tank_blue-392x147.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/tank_blue-768x287.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/tank_blue-114x43.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/tank_blue-474x177.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/tank_blue-473x177.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/tank_blue-727x272.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/tank_blue.png 800w" sizes="auto, (max-width: 392px) 100vw, 392px" /></a></p>
<p><a title="Laboratory Model with Box Tank in the Towing Tank in Beam Sea." href="http://www.sva-potsdam.de/wp-content/uploads/2016/11/model_beam_seas.png"><img loading="lazy" decoding="async" class="alignnone wp-image-5756 size-medium" title="Schiffsmodell beim Rolldämpfungsversuch mit Boxtank." src="http://www.sva-potsdam.de/wp-content/uploads/2016/11/model_beam_seas-392x133.png" alt="model_beam_seas" width="392" height="133" srcset="https://www.sva-potsdam.de/wp-content/uploads/2016/11/model_beam_seas-392x133.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/model_beam_seas-768x261.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/model_beam_seas-114x39.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/model_beam_seas-474x161.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/model_beam_seas-473x161.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/model_beam_seas-727x247.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/model_beam_seas.png 800w" sizes="auto, (max-width: 392px) 100vw, 392px" /></a></p>
</div>
<div class="sva_text_container">
Within the framework of the research project ROLLTANK sponsored by the BMWI, a method for improving the determination of the flow processes in roll damping tanks was developed. The improved design of this type of installation can be used with a view to an optimum seakeeping behavior of a ship. The method development was supported by accompanying laboratory tests. In addition to investigations of a laboratory model of a RoPax vessel in the towing tank, further useful data for the validation of the method to be developed was provided through the use of a modified roll system with an electric drive for the excitation of a roll damping tank, isolated from the vessel, to defined sinusoidal vibrations.</p>
<p>Two Frahm tanks and a box tank were designed for testing on the roll system. The experimental program included measurements with sinusoidal excitation, variation of the frequency, roll amplitude, and the fill level of the tank. Differing variants of internals within the tanks were taken into account. The evaluation of the measurements was supported by video recordings and the use of ultrasound probes.</p>
<p>The laboratory tests were carried out in the towing tank with specially designed Frahm and Box tanks with variation of metacentric height, wave height, wave length as well as the sea state in regular and irregular seas. In order to ensure defined boundary conditions for the validation, the tests were carried out in beam seas without any speed.</p>
<p>For further evaluation of the laboratory tests and process development, RANSE calculations were performed for selected cases.</p>
<p>The starting point for the method to be developed was the Morison equation, which was expanded with respect to the parts of a developed vortex system  proportional to speed and acceleration. As a result, coefficients of resistance and damping are supplied which then are corrected with empirical formulas depending on the obstruction in the tanks. In the further development, shallow water equations were used, which were extended for the developed non-linear parts. These equations formed the basis for subsequent non-linear tank calculations using the nonlinear strip method ROLF. To this end, the ROLF method was extended with additional tools for tank calculation, which distinguishes it from the STRIP method (linear strip method form the software system UTHLANDE). Extensive simulations were carried out using the new method and were compared with the results of the laboratory tests for their validation.</p>
<p>Extensive validation and comparison with previous methods show that the implementation of the new method in ROLF allows a fast and efficient prediction of the roll damping effect of the tank, especially in the case of large roll amplitudes. For the first time, and in contrast to the STRIP method, effects of parametric roll excitation of ships with roll damping tanks can also be determined. The use of the method for projects in the shipbuilding industry is therefore sensible in areas where minimal  roll movements of the ship during operation are important even in extreme seas to minimize the risks to crew and ship. In addition to passenger ships and yachts, the future market is being seen in applications for offshore industrial projects. These include work boats and supply vessels for wind power and offshore installations, where it must be possible to come alongside and land in strong sea states. Lastly and importantly, the use of the procedure contributes to advances in ship safety.</p>
<p>Author: Dr.-Ing. Matthias Fröhlich, Schiffbau-Versuchsanstalt Potsdam GmbH</p>
<div class="sva_clear"></div>
</div>
<p>&nbsp;</p>
<div class="sva_bild_floatBTN" style="margin: 0 auto; width: 75%;">
<p><a title="RANSE Simulation: Frahm Tank with Diaphragms." href="http://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_u_tank.png"><img loading="lazy" decoding="async" class="alignnone wp-image-5754" title="CFD-Simulation eines Rolldämpfungstanks (Frahmtank)." src="http://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_u_tank-392x225.png" alt="cfd_u_tank" width="261" height="150" srcset="https://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_u_tank-392x225.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_u_tank-768x441.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_u_tank-114x65.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_u_tank-474x272.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_u_tank-473x271.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_u_tank-727x417.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_u_tank.png 800w" sizes="auto, (max-width: 261px) 100vw, 261px" /></a></p>
<p><a title="Vortex Formation in One of the Two Sides of a Frahm Tank, Simulation Laboratory experiment." href="http://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_video_combined.png"><img loading="lazy" decoding="async" class="alignnone wp-image-5765" title="Vergleich von CFD-Simulation eines Frahmtanks mit Experiment." src="http://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_video_combined-392x149.png" alt="cfd_video_combined" width="393" height="150" srcset="https://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_video_combined-392x149.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_video_combined-768x293.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_video_combined-1024x390.png 1024w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_video_combined-114x43.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_video_combined-474x181.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_video_combined-473x180.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_video_combined-727x277.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/cfd_video_combined.png 1306w" sizes="auto, (max-width: 393px) 100vw, 393px" /></a></p>
<p><a title="Damping Moment of a Box Tank, Roll Amplitude 2° Red, 4° Black." href="http://www.sva-potsdam.de/wp-content/uploads/2016/11/diagram.png"><img loading="lazy" decoding="async" class="alignnone wp-image-5755" title="Dämpfungsmoment eines Boxtanks." src="http://www.sva-potsdam.de/wp-content/uploads/2016/11/diagram-392x262.png" alt="diagram" width="225" height="150" srcset="https://www.sva-potsdam.de/wp-content/uploads/2016/11/diagram-392x262.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/diagram-768x513.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/diagram-114x76.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/diagram-474x316.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/diagram-473x317.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/diagram-727x486.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2016/11/diagram.png 800w" sizes="auto, (max-width: 225px) 100vw, 225px" /></a></p>
</div>
<div class="sva_clear"></div>
</div><p>The post <a href="https://www.sva-potsdam.de/en/calculation-method-for-the-design-of-roll-damping-tanks/">Calculation Method for the Design of Roll Damping Tanks</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CFD-Based Optimisation of a Propeller Wash Deflection Behind an Inland Icebreaker</title>
		<link>https://www.sva-potsdam.de/en/adm-juli-2016/</link>
		
		<dc:creator><![CDATA[pa]]></dc:creator>
		<pubDate>Mon, 20 Jun 2016 08:00:29 +0000</pubDate>
				<category><![CDATA[Archive]]></category>
		<guid isPermaLink="false">http://www.sva-potsdam.de/adm-juli-2016-2/</guid>

					<description><![CDATA[<p>The Schiffbau-Versuchsanstalt Potsdam Potsdam GmbH (SVA) (Potsdam Model Basin) was commissioned by the Special Unit for Mechanical Engineering (FMM) of the Waterways and Shipping Office Minden, to design and calculate a wash deflection behind a ship. The inland icebreaker &#8220;Turmfalke&#8221; is to be used during the ice-free period, among other things, to stir up and flush the silt deposited on the bottom of the waterways. The propeller wash of the vessel is to be redirected by a device so that</p>
<p>The post <a href="https://www.sva-potsdam.de/en/adm-juli-2016/">CFD-Based Optimisation of a Propeller Wash Deflection Behind an Inland Icebreaker</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></description>
										<content:encoded><![CDATA[<div id="idTextPanel" class="jqDnR">
<div class="sva_bild_floatLFT">
<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_01_small.png"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4882" src="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_01_small-392x201.png" alt="AdM_Strahlumlenkung_01_small" width="392" height="201" srcset="https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_01_small-392x201.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_01_small-768x395.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_01_small-114x59.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_01_small-474x244.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_01_small-473x243.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_01_small-727x373.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_01_small.png 800w" sizes="auto, (max-width: 392px) 100vw, 392px" /></a></p>
<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_02_small.png"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4883" src="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_02_small-392x201.png" alt="AdM_Strahlumlenkung_02_small" width="392" height="201" srcset="https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_02_small-392x201.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_02_small-768x395.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_02_small-114x59.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_02_small-474x244.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_02_small-473x243.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_02_small-727x373.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_02_small.png 800w" sizes="auto, (max-width: 392px) 100vw, 392px" /></a></p>
<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_03_small.png"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4884" src="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_03_small-392x201.png" alt="AdM_Strahlumlenkung_03_small" width="392" height="201" srcset="https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_03_small-392x201.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_03_small-768x395.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_03_small-114x59.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_03_small-474x244.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_03_small-473x243.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_03_small-727x373.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_03_small.png 800w" sizes="auto, (max-width: 392px) 100vw, 392px" /></a></p>
<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_04_small.png"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4885" src="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_04_small-392x201.png" alt="AdM_Strahlumlenkung_04_small" width="392" height="201" srcset="https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_04_small-392x201.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_04_small-768x395.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_04_small-114x59.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_04_small-474x244.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_04_small-473x243.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_04_small-727x373.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_04_small.png 800w" sizes="auto, (max-width: 392px) 100vw, 392px" /></a></p>
<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_05_small.png"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4886" src="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_05_small-392x201.png" alt="AdM_Strahlumlenkung_05_small" width="392" height="201" srcset="https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_05_small-392x201.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_05_small-768x395.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_05_small-114x59.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_05_small-474x244.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_05_small-473x243.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_05_small-727x373.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_05_small.png 800w" sizes="auto, (max-width: 392px) 100vw, 392px" /></a></p>
<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_06_small.png"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4887" src="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_06_small-392x201.png" alt="AdM_Strahlumlenkung_06_small" width="392" height="201" srcset="https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_06_small-392x201.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_06_small-768x395.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_06_small-114x59.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_06_small-474x244.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_06_small-473x243.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_06_small-727x373.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_06_small.png 800w" sizes="auto, (max-width: 392px) 100vw, 392px" /></a></p>
<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_07_small.png"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4888" src="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_07_small-392x201.png" alt="AdM_Strahlumlenkung_07_small" width="392" height="201" srcset="https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_07_small-392x201.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_07_small-768x395.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_07_small-114x59.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_07_small-474x244.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_07_small-473x243.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_07_small-727x373.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_07_small.png 800w" sizes="auto, (max-width: 392px) 100vw, 392px" /></a></p>
<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2016/03/AdM_Strahlumlenkung_Diag_small.png"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4896" src="http://www.sva-potsdam.de/wp-content/uploads/2016/03/AdM_Strahlumlenkung_Diag_small-392x201.png" alt="AdM_Strahlumlenkung_Diag_small" width="392" height="201" srcset="https://www.sva-potsdam.de/wp-content/uploads/2016/03/AdM_Strahlumlenkung_Diag_small-392x201.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2016/03/AdM_Strahlumlenkung_Diag_small-768x395.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2016/03/AdM_Strahlumlenkung_Diag_small-114x59.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2016/03/AdM_Strahlumlenkung_Diag_small-474x244.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2016/03/AdM_Strahlumlenkung_Diag_small-473x243.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2016/03/AdM_Strahlumlenkung_Diag_small-727x373.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2016/03/AdM_Strahlumlenkung_Diag_small.png 800w" sizes="auto, (max-width: 392px) 100vw, 392px" /></a></p>
<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_01_small.png"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4890" src="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_01_small-392x201.png" alt="AdM_Strahlumlenkung_Foto_01_small" width="392" height="201" srcset="https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_01_small-392x201.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_01_small-768x395.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_01_small-114x59.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_01_small-474x244.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_01_small-473x243.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_01_small-727x373.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_01_small.png 800w" sizes="auto, (max-width: 392px) 100vw, 392px" /></a></p>
<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_02_small.png"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4891" src="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_02_small-392x199.png" alt="AdM_Strahlumlenkung_Foto_02_small" width="392" height="199" srcset="https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_02_small-392x199.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_02_small-768x390.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_02_small-114x58.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_02_small-474x241.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_02_small-473x240.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_02_small-727x369.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_02_small.png 800w" sizes="auto, (max-width: 392px) 100vw, 392px" /></a></p>
<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_03_small.png"><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-4892" src="http://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_03_small-392x199.png" alt="AdM_Strahlumlenkung_Foto_03_small" width="392" height="199" srcset="https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_03_small-392x199.png 392w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_03_small-768x390.png 768w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_03_small-114x58.png 114w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_03_small-474x241.png 474w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_03_small-473x240.png 473w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_03_small-727x369.png 727w, https://www.sva-potsdam.de/wp-content/uploads/2015/06/AdM_Strahlumlenkung_Foto_03_small.png 800w" sizes="auto, (max-width: 392px) 100vw, 392px" /></a></p>
</div>
<div class="sva_text_container">
<p><!--h3>Task</h3-->
The Schiffbau-Versuchsanstalt Potsdam Potsdam GmbH (SVA) (Potsdam Model Basin) was commissioned by the Special Unit for Mechanical Engineering (FMM) of the Waterways and Shipping Office Minden, to design and calculate a wash deflection behind a ship. The inland icebreaker &#8220;Turmfalke&#8221; is to be used during the ice-free period, among other things, to stir up and flush the silt deposited on the bottom of the waterways. The propeller wash of the vessel is to be redirected by a device so that the best possible disturbance and resuspension of deposited silt is reached at the water&#8217;s bottom. A similar system has already been provided to the client by another company and its successful operation has been repeatedly demonstrated. </p>
<p>The task was divided into 4 work packets: In a preliminary study, a variety of possible baffles were to be fundamentally compared. Then a selected variant would be optimised with regard to its effect on the water bottom. This was followed by the study of the effectiveness at different depths, and the study of various steering flaps to assist manoeuvrability. </p>
<h3>Ship and Propeller</h3>
<table class="sva-article-table">
<tbody>
<tr>
<td style="text-align: left;" colspan="3" width="500">
<h5>Main particulars of the ship</h5>
</td>
</tr>
<tr>
<td>Length between perpendiculars</td>
<td><em>L</em><sub>PP</sub> [m]</td>
<td>20.13</td>
</tr>
<tr>
<td>Breadth</td>
<td><em>B</em> [m]</td>
<td>7.10 [m]</td>
</tr>
<tr>
<td>Draught</td>
<td><em>T</em> [m]</td>
<td>1.40</td>
</tr>
<tr>
<td>Displacement</td>
<td><em>∇</em> [m<sup>3</sup>]</td>
<td>114.6</td>
</tr>
</tbody>
</table>
<p>&nbsp;<br />
<br />
With the help of a sea trial protocol of a sister ship, a propeller of the Wageningen B-series was selected which nearly achieves the characteristics of the sea trial. The radial thrust and torque distribution of this propeller was determined by SVA&#8217;s own program VORTEX and modelled through an actuator disc within CFD calculations</p>
<h3>Deflection Device</h3>
<p>The geometry of the deflection device is subject to a few restrictions. The depth of the device should not exceed the ship. Along with that, the feasibility of using simple steel construction methods was looked into.</p>
<h3>Constraints</h3>
<p>The draught of the ship in the calculations was <em>D</em>&nbsp;=&nbsp;1.4&nbsp;m. The water depth was set in the preliminary study and during the optimisation at <em>h</em>&nbsp;=&nbsp;2.5&nbsp;m. To determine the effectiveness at other water depths, the effect of wash deflection at <em>h</em>&nbsp;=&nbsp;2&nbsp;m, <em>h</em>&nbsp;=&nbsp;3&nbsp;m and <em>h</em>&nbsp;=&nbsp;4&nbsp;m were calculated. The geometry of the icebreaker was provided by the client. At the location of the propeller a cylindrical region was defined, in which the volume force of the actuator disc was induced. Down below, the calculation area was limited by the water bottom and from above by the surface of the water which was defined as fixed. For the preliminary study a symmetrical situation was adopted (calculation of the half ship / half the region, no twist in the propeller wash) to shorten the calculation time. To optimise the selected variant out of this, the entire flow field was calculated around the ship. </p>
<h3>Analysis of the Numerical Simulations</h3>
<p>The effect of wash deflection on the water bottom was calculated. The sand roughness of silt soil was assumed <em>k</em>&nbsp;=&nbsp;0.06&nbsp;mm (citation in consultation with the client). Through adoption of a fixed bottom, no change in the ground topology by the wash effect could be registered. Above a certain shear stress, a Bingham fluid like slush begins to flow. Therefore, the essential design criterion was the size of the area of the waterway bed where a wall shear stress of <em>&tau;</em>&nbsp;=&nbsp;120&nbsp;Pa is exceeded. As a further assessment criterion, the pressure on the bottom was evaluated.</p>
<h3>Comparison of Different Deflections &#8211; Preliminary Study</h3>
<p>The calculations showed that a side plate is required for effective wash deflection. Through this, the spreading of the wash to the side is significantly reduced. Without a side plate, the required wall shear stress of <em>&tau;</em>&nbsp;=&nbsp;120&nbsp;Pa is not reached. Flow permeable gaps in the deflector should be avoided, as these can substantially reduce the effect of the deflection. The images to the left show the resulting values in dependence of the selected geometry variant (figures&nbsp;1-6). The closed tunnel variant (figure&nbsp;6) was the most effective and was selected by the client for optimisation.</p>
<h3>Optimization of the Tunnel Variant</h3>
<p>For the geometric optimisation of the tunnel, a parametric model was developed for the CAE program &#8220;CAESES&#8221;. The width of the entry area was set to 1.30&nbsp;m. In this way, function is guaranteed even with slight rudder deflections. Through the dependency of the geometry on defined parameters, it could be changed fully automatically for optimisation. The vertical position of the upper edge of the tunnel entrance, the height of the entrance area, the length of the tunnel, the ratio of entry area to exit area and the ratio of length-to-width of the exit area were optimised using parametric variation in regard to the resulting bottom surface with a wall shear stress of <em>&tau;</em>&nbsp;>&nbsp;120&nbsp;Pa.</p>
<h3>Results of the Optimization</h3>
<p>The top of the tunnel is located just below the surface of the water. To prevent the deflected wash from flowing over, the area between the ship and deflection device should be covered at the surface of the water. The breadth of the water bottom area experiencing a wall shear stress of <em>&tau;</em>&nbsp;>&nbsp;120&nbsp;Pa is about 2.5&nbsp;m, the length  is about 2&nbsp;m. The wall shear stress and the pressure at the water bottom which are generated by the optimum tunnel variant is shown in figure&nbsp;7. To demonstrate the effectiveness of the optimised tunnel geometry at different water depths, additional calculations at <em>h</em>&nbsp;=&nbsp;2, 3 and 4&nbsp;m were performed. The results show a moderate decrease in the effectiveness depending on the water depth. At 4&nbsp;m water depth 120&nbsp;Pa wall shear stress is no longer achieved (see graph in figure&nbsp;8). </p>
<h3>Evaluation of the Results </h3>
<p>Because of the applied simplifications (fixed water surface, quasi-static calculations, actuator disc, no change in the ground topology) the results may only be qualitative. The pressure on the water bottom corresponds to 28.000&nbsp;Pa&nbsp;(N/m^2) at a depth of <em>h</em>&nbsp;=&nbsp;2.5&nbsp;m. Such pressure should lead to a deformation of mud at the water bottom (washed out cavity) which will again significantly increase the flushing effect.</p>
<h3>Comparison of Theory (SVA Simulations) and Practice (Trial Run, see below)</h3>
<p>The optimisation of the device was carried out at a low system speed, because the self propulsion point was achieved in the calculations with P<sub>Motor</sub>&nbsp;=&nbsp;2/3&nbsp;P<sub>Motor max</sub> below 5&nbsp;km/h. However, the device appears to produce a significantly lower resistance in reality. This suggests that the specification of a &#8220;fixed&#8221; water surface &#8211; despite a plate between tunnel entrance and ship &#8211; is not optimal under these circumstances. In operation, the device would clearly be washed over. To reduce the speed, the propeller wash is to be restricted in the future through additional lateral plates. </p>
<h3>Real-World Implementation of the Wash Deflector</h3>
<p>All following contents shown were edited by the company &#8220;TECHNOMAR GmbH &#038; Co. KG&#8221; and provided to SVA through the Special Unit for Mechanical Engineering (FMM) of the Waterways and Shipping Office Minden from the sea trial protocol. </p>
<h5>Manoeuvring Behaviour</h5>
<p>The ship carries out rudder manoeuvres reliably. Also, no problems arise when reversing. The device reduces the boat speed under full load from 15&nbsp;km/h to&nbsp;12&nbsp;km/h. The skipper states: &#8220;A safe manoeuvring is possible. There are no restrictions.&#8221;</p>
<h5>Reviewing the Effectiveness</h5>
<p>The provided test course has been driven through and the water depths read. The water depth is 2.4&nbsp;m on average. Then, a distance of 400 to 500&nbsp;m is covered in a total of 3 runs with steps of different speeds. Through the flushing process the whirling water came to the surface and was deep black with sediments. After the 3rd passage gas bubbles (fermentation gases) were shown on the surface. The experiment was ended and the device taken out of the water. The test course was driven again and the water depth determined. It was now measured at around 2.80&nbsp;m. The waterway course was deepened in this experiment by about 40&nbsp;cm. The thrust vectoring device must now be tested in further experiments on the effectiveness of the flushing. This is carried out and documented by the WSA-Meppen. All participants believe that the device is an improvement in controlling the silt problem on the Ems River.
</p></div>
<p>Courtesy of:</p>
<p>Fachstelle Maschinenwesen Mitte<br />
at Minden Waterways and Shipping Office<br />
Am Hohen Ufer 1-3<br />
32425 Minden</p>
<p>Author: Dipl.-Ing. E. Schomburg</p>
</div><p>The post <a href="https://www.sva-potsdam.de/en/adm-juli-2016/">CFD-Based Optimisation of a Propeller Wash Deflection Behind an Inland Icebreaker</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SVA Items 14/2014</title>
		<link>https://www.sva-potsdam.de/en/sva-items-142014/</link>
		
		<dc:creator><![CDATA[pa]]></dc:creator>
		<pubDate>Tue, 17 Jun 2014 10:45:58 +0000</pubDate>
				<category><![CDATA[Archive]]></category>
		<guid isPermaLink="false">http://www.sva-potsdam.de/sva-items-142014-2/</guid>

					<description><![CDATA[<p>SVA Items 14/2014</p>
<p>The post <a href="https://www.sva-potsdam.de/en/sva-items-142014/">SVA Items 14/2014</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2016/06/items_14_2014.pdf">SVA Items 14/2014</a></p><p>The post <a href="https://www.sva-potsdam.de/en/sva-items-142014/">SVA Items 14/2014</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SVA Items 13/2012</title>
		<link>https://www.sva-potsdam.de/en/sva-items-132012/</link>
		
		<dc:creator><![CDATA[pa]]></dc:creator>
		<pubDate>Sun, 17 Jun 2012 10:44:52 +0000</pubDate>
				<category><![CDATA[Archive]]></category>
		<guid isPermaLink="false">http://www.sva-potsdam.de/sva-items-132012-2/</guid>

					<description><![CDATA[<p>SVA Items 13/2012</p>
<p>The post <a href="https://www.sva-potsdam.de/en/sva-items-132012/">SVA Items 13/2012</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2016/06/items_13_2012.pdf">SVA Items 13/2012</a></p><p>The post <a href="https://www.sva-potsdam.de/en/sva-items-132012/">SVA Items 13/2012</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SVA Items 12/2010</title>
		<link>https://www.sva-potsdam.de/en/sva-items-122010/</link>
		
		<dc:creator><![CDATA[pa]]></dc:creator>
		<pubDate>Thu, 17 Jun 2010 10:44:09 +0000</pubDate>
				<category><![CDATA[Archive]]></category>
		<guid isPermaLink="false">http://www.sva-potsdam.de/sva-items-122010-2/</guid>

					<description><![CDATA[<p>SVA Items 12/2010</p>
<p>The post <a href="https://www.sva-potsdam.de/en/sva-items-122010/">SVA Items 12/2010</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2016/06/items_12_2010.pdf">SVA Items 12/2010</a></p><p>The post <a href="https://www.sva-potsdam.de/en/sva-items-122010/">SVA Items 12/2010</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SVA Items 11/2008</title>
		<link>https://www.sva-potsdam.de/en/sva-items-112008/</link>
		
		<dc:creator><![CDATA[pa]]></dc:creator>
		<pubDate>Tue, 17 Jun 2008 10:43:11 +0000</pubDate>
				<category><![CDATA[Archive]]></category>
		<guid isPermaLink="false">http://www.sva-potsdam.de/sva-items-112008-2/</guid>

					<description><![CDATA[<p>SVA Items 11/2008</p>
<p>The post <a href="https://www.sva-potsdam.de/en/sva-items-112008/">SVA Items 11/2008</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2016/06/items_11_2008.pdf">SVA Items 11/2008</a></p><p>The post <a href="https://www.sva-potsdam.de/en/sva-items-112008/">SVA Items 11/2008</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SVA Items 9/2004</title>
		<link>https://www.sva-potsdam.de/en/sva-items-92004/</link>
		
		<dc:creator><![CDATA[pa]]></dc:creator>
		<pubDate>Thu, 17 Jun 2004 10:41:23 +0000</pubDate>
				<category><![CDATA[Archive]]></category>
		<guid isPermaLink="false">http://www.sva-potsdam.de/sva-items-92004-2/</guid>

					<description><![CDATA[<p>SVA Items 09/2004</p>
<p>The post <a href="https://www.sva-potsdam.de/en/sva-items-92004/">SVA Items 9/2004</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><a href="http://www.sva-potsdam.de/wp-content/uploads/2016/06/items_09_2004.pdf">SVA Items 09/2004</a></p><p>The post <a href="https://www.sva-potsdam.de/en/sva-items-92004/">SVA Items 9/2004</a> first appeared on <a href="https://www.sva-potsdam.de/en/">SVA</a>.</p>]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>